Profile:
        CZPTR SHKL-Y sequence flooded variety screw chiller is an energy-saving and large-effectiveness central air-conditioning chiller which developed and manufactured by CZPT.  All CZPT chillers are manufacturing facility examined underneath load conditions to guarantee straightforward installation for users. The unit adopts a substantial-effectiveness oil separator with the impacts and intercepts oil separation technologies. The evaporator adopts the ejector oil return technological innovation. That helps make the EER earlier mentioned five.two, and the EER of the variable frequency flooded chiller can attain 7..
This sequence is ideal for a variety of industrial and civil buildings this sort of as accommodations, restaurants, searching malls, hospitals, factories, and so forth.

Functions:
1. High Efficiency

  • Utilizing flooded type evaporator, preserving power by fifteen%~25% in contrast with equivalent dry sort evaporator chillers.
  • Utilizing screw compressor, substantial effectiveness heat-exchanger and electronic growth valve, 4 elements matched properly which make large effectiveness of entire unit.

two. Reputable Operation

  • seven safeguards can guarantee the chiller steady procedure.
  • All chillers are analyzed by security inspection program just before shipping and delivery, to ensure the functionality.

three. CZPT Control

  • CZPT microcomputer controller, provides most straightforward and thoughtful operation interface, deliver comments of maintenance info well timed.
  • The chiller management technique can be connected to the user’s central management technique, consumer can verify the operation standing at any time.

four. Straightforward Set up and Routine maintenance

  • The chiller is stuffed with refrigerant and lubricating oil ahead of leaving the factory. The user only demands to join the inlet and outlet pipes and the energy supply to run.
  • The control interface straight displays the fault merchandise, which is handy for well timed know the faults and elimination.

five. Non-Standard Design Obtainable

  • We provide R22,R407,R134a refrigerant choices in accordance to consumer requirements.
  • We can also make the specific chillers these kinds of as anti-corrosion and explosion-evidence models in accordance to the customer’s request.

CZPT Info

Model      SHKL- 400WSY 490WSY 540WSY 610WSY 740WSY 850WSY 970WSY 1090WSY 1180WSY 1310WSY 1600WSY 1850WSY
Refrigerant R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a
Nominal cooling capability ×1000kcal/h 341.4 274.3 421.3 296.six 464.3 337.nine 522.eight 411.nine 638 470.three 732.6 534.8 832.3 607.one 939 655.two 1014.six 725.seven 1126.four 806.five 1374 880.five 1592.4 999.1
KW 397 319 490 345 540 393 608 479 742 547 852 622 968 706 1092 762 1180 844 1310 938 1598 1571 1852 1162
USRT 113 91 139 ninety eight 154 112 173 136 211 156 242 177 275 201 310 217 336 240 372 267 454 291 527 330
Enter electrical power kw sixty seven.4 fifty one.2 eighty two.2 fifty six 88.8 sixty three.6 101.three 77.8 124.five 87.nine 141 ninety eight.7 158.5 111.six 179.2 121.one 191.nine 139.1 211.9 153.6 263 168.eight 304 a hundred ninety.9
Comp.existing(A) 121.eight ninety three.5 150.7 107.nine 164.7 124.1 189.eight 143.seven 224 162.5 250 178.6 287 210 324 210 347 260 385 289 469.four 306.seven 539.three 354.one
Electrical power CZPT 3Phase-380V-50Hz  
CZPT Unit Reverse phase protection,stage reduction safety,overcurrent defense,higher and reduced voltage protection,lower temperature safety,h2o flow protection
Number Of CZPT Circuit 1
 Capacity Manage(%) stepless Ability or ,twenty five,50,75,100 stepless Capacity or ,twenty five,fifty,seventy five,a hundred
Refrigerant charge  152 122 188 132 207 151 233 184 285 210 327 239 372 271 419 292 453 324 503 360 613 393 711 446
Condenser Shell-and-Tube Variety
Water Facet max Pressure(MPa) one
Dia.of pipe to Condenser(inch) 4″ 4″ 5″ 5″ 5″ 6″ 6″ 6″ 8″ 8″ 8″ 8″
CZPT H2o Circulation (m³/h) 79.9 63.seven 98.four 69 108.1 78.five 122 ninety five.8 149 109.two one hundred seventy.8 123.9 193.7 140.6 218.six 151.9 235.9 169.1 261.7 187.7 320 205.one 370.eight 232.seven
Condenser Drinking water Pressure drop( Kpa) 70 72 75 seventy seven 79 eighty 83 eighty five ninety 95 one hundred 106
Evaporator Flooded Type
Drinking water Aspect max Pressure(MPa) 1
Dia.of pipe to Evaporator(inch) 4″ 4″ 5″ 5″ 5″ 6″ 6″ 6″ 8″ 8″ 8″ 8″
Chilled H2o Movement(m³/h) 68.3 fifty four.9 84.three fifty nine.3 ninety two.9 67.6 104.six 82.4 127.six 94.1 146.5 107 166.5 121.four 187.eight 131 202.9 145.one 225.3 161.3 274.8 176.one 318.five 199.8
Evaporator Water Strain drop(KPa) 75 seventy six 78 79 80 82 85 88 ninety five one hundred 107 110
Running noise Db(A) 65 60 66 sixty one 67 62 69 sixty four 70 65 seventy two sixty seven 73 sixty eight 73 sixty eight 76 70 seventy six 70 seventy eight seventy two 78 72
Complete Excess weight(kg) 1540 1420 1780 1650 2571 1950 2550 2410 2930 2760 3540 3320 4050 3840 4640 4450 5360 5200 6100 6000 6800 6500 7200 7000
Working Bodyweight(kg) 1850 1700 2140 1980 2410 2340 3060 2890 3520 3310 4250 3980 4860 4610 5570 5340 6430 6240 7320 7200 8160 7800 8640 8400

 

Model      SHKL- 800WDY 980WDY 1080WDY 1220WDY 1480WDY 1700WDY 1940WDY 2180WDY 2360WDY 2620WDY 3200WDY 3700WDY
Refrigerant R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a R22 R134a
Nominal cooling potential ×1000kcal/h 682.7 548.six 842.six 593.three 928.6 675.eight 1045.6 823.seven 1276 940.seven 1465.two 1069.six 1664.7 1214.one 1877.nine 1310.four 2571.2 1451.4 2252.eight 1613.one 2748.one 1761 3184.9 1998.3
KW 794 638 980 690 1080 786 1216 958 1484 1094 1704 1244 1936 1412 2184 1524 2360 1688 2620 1876 3196 2048 3704 2324
USRT 226 181 279 196 307 223 346 272 422 311 485 354 550 401 621 433 671 480 745 533 909 582 1053 661
Enter energy kw 134.8 102.4 164.four 112 177.6 127.2 202.6 155.six 249 176 282 197 317 223 358 242 384 278 424 307 526 338 608 382
Comp.current(A) 243.six 187 301.four 215.eight 329.4 248.2 379.6 287.4 448 325 five hundred 357 574 420 648 420 694 520 770 578 939 613 1079 708
Energy CZPT 3Phase-380V-50Hz
CZPT Device Reverse section protection,phase loss safety,overcurrent protection,large and reduced voltage defense,lower temperature safety,h2o circulation security
Quantity Of CZPT Circuit 1
 Capacity Manage(%) Stepless Potential or ,twenty five,37.5,50,62.5,75,87.5,one hundred stepless Capacity or ,25,37.five,50,62.5,75,87.five,one hundred
Refrigerant charge  305 245 376 265 415 302 467 368 570 420 654 478 743 542 838 585 906 648 1006 720 1227 786 1422 892
Condenser   Shell-and-Tube Kind
H2o Facet max Pressure(MPa) 1
Dia.of pipe to Condenser(inch) 5″ 6″ 6″ 8″ 8″ 8″ 10″ 10″ 10″ 10″ 10″ 12″
CZPT H2o Movement (m³/h) 159.seven 127.three 196.8 137.9 216.three 157 244 191.five 298 218.4 341.five 247.nine 387.4 281.two 437.two 303.seven 471.eight 338.one 523.four 375.4 640.one 410.two 741.5 465.3
Condenser H2o Strain drop( Kpa) 80 eighty five 87 ninety ninety four 96 100 one zero five one hundred ten a hundred and fifteen 118 a hundred twenty five
Evaporator  Flooded Type
Water Side max Stress(MPa) one
Dia.of pipe to Evaporator(inch) 5″ 6″ 6″ 8″ 8″ 8″ 10″ 10″ 10″ 10″ 10″ 12″
Chilled Drinking water Stream(m³/h) 136.5 109.seven 168.5 118.seven 185.7 135.2 209.one 164.seven 255.two 188.one 293 213.nine 332.9 242.8 375.six 262.1 405.8 290.3 450.six 322.six 549.6 352.two 637 399.7
Evaporator H2o Force drop(KPa) 84 89 92 ninety five ninety nine one hundred and five 107 one hundred ten 115 one hundred twenty one hundred twenty five a hundred thirty five
Operating sounds Db(A) 70 65 seventy one 66 seventy three sixty seven 75 70 seventy seven seventy two 79 seventy four seventy nine 74 80 75 seventy seven seventy two 79 seventy four seventy nine 74 80 75
Complete Excess weight(kg) 4200 4050 4900 4720 5520 5280 6230 6040 6780 6580 7200 7030 8060 7920 8850 8640 9320 9230 9910 9850 10800 15710 11500 11100
Working Bodyweight(kg) 5040 4860 5880 5660 6620 6340 7480 7250 8140 7900 8640 8440 9670 9500 10620 1571 11180 11080 11890 11820 12960 12240 13800 13320

Notice:
one. Nominal cooling potential primarily based on: Evaporator inlet and outlet h2o temperature 12ºC/7ºC, Condenser inlet and outlet h2o temperature 30ºC/35ºC, Fouling coefficient .088mtwo.ºC/KW
two. Chilled drinking water temperature range: 5ºC ~ fifteen ° C R134a: 5ºC ~20ºC
3. CZPT h2o temperature variety: 15ºC ~ forty ° C R134a: 20ºC ~ 45ºC
4. Specifications and dimensions will be subject to modify with out recognize.

About CZPTR
      CZPT Freezing CZPTry (HangZhou)Co., Ltd. is a joint undertaking which was proven by domestic Huizhuo and Japan Ronghe corporation with a total expense of fifty million Yuan in 2017. It situated in HangZhou CZPT and Technological CZPT Zone . Combined with Japan R&D heart and ZheJiang College of CZPT, We are dedicated to industrial chiller, central air conditioner, magnetic centrifugal chiller R&D and manufacture.

Our Major Item:
one)   CZPTic Bearing Centrigufal Chiller
2)   Water cooled CZPT Chiller, Air cooled screw Chiller, Flooded sort CZPT Chiller ,Evaporative Cooled CZPT Chiller
three)   Water cooled Scroll Chiller, Air cooled Scroll Chiller
4)   Water-cooled Packaged air conditioner, Air-cooled Packaged air conditioner , clean continuous temperature and humidity air conditioner, CZPT air conditioning
five)   Low temperature chiller(0ºC to -50ºC)
six)   Anti-corrosion Chiller , Explosion-proof Chiller, and many others.
 

Manufacturing unit SHOW        
We have our very own laboratories and prefessional screening Line. All CZPTR chillers are manufacturing unit examined underneath load problems to guarantee straightforward set up for users.                                                                    

 

Instances
Product Cases from our customers’ manufacturing unit

Package
CZPT film+plywood case+wooden frame 

1. A number of packing. proved by assessments of the compression resistance and throwing. and highly secured.
2. Plywood scenario packing .high resistance of burst toughness, ring crush toughness and tearing power.
3. CZPT body packing. Damp-proved and hight resistance of burst strength and ring crush power.

FAQ
Q1: Are you a manufacturer? 
A1: Yes, we have much more than 10 many years in water chiller organization. New plant was bulit in 2017 in HangZhou CZPT&Technological CZPT Zone. Welcome to go to us anytime!

Q2: Could you help us to advocate the design for our task? 
A2: Of course, we have engineer to check out the specifics and make the scheme for you. Based on the following:
1)CZPT capability
two) Refrigerant
three) Ambient temperature
4)Voltage
5) For what sector
six)The constructing drawing(if you have)
7)Any other special demands.  

Q3: How to make certain your solution with very good good quality? 
A3: We use the effectively-know brand equipment, this sort of as CZPT , CZPT, danfoss compressor, Emerson growth Valve, Siemens controller.  All CZPTR chillers are factory examined beneath load problems to ensure good top quality and easy installation for customers.

This autumn: What’s the warrenty? 
A4: 1 year warrenty for free if verified by equally side injury in the quality cause. 

Q5: Whats your payment term?
A5: We accept TT, LC, CZPT CZPT, and so on. Generally ,30% deposit for manufacturing, 70% balance just before cargo.

Q6: How can I place an purchase? 
A6: Contact us via manufactured in China or make contact with beneath info.
Ms.Livia
Tel: twenty 31605718-820
Cellular: 13595716431

 

Large Capacity Flooded Type Water Cooled Water Chiller for Chemical Factory

English